Control of Power Inverters in Renewable Energy and Smart Grid Integration电力—ch6.pdf

Control of Power Inverters in Renewable Energy and Smart Grid Integration电力—ch6.pdf

  1. 1、本文档共21页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
电工电子,电器,安装,维修,电磁炉,线路图,电路图,元器件,监测,故障,电气,PID

6 Cascaded Current-Voltage H∞ Repetitive Control Both the THD of the microgrid voltage and the THD of the current exchanged with the grid need to be kept low according to industrial regulations. It has been shown that it is not a problem to obtain low THD for either the microgrid voltage (Chapters 4 and 5) or for the current exchanged with the grid (Chapter 3). However, it has been a challenge to obtain low THD for both the voltage and the current simultaneously. In this chapter, the advantages of the voltage and current controllers based on H ∞ and repetitive control techniques, presented in Chapters 3 and 5 respectively, are brought together to achieve low THD for both the microgrid voltage and the current exchanged with the grid. It is not a simple combination of the two control strategies but a complete re-design after realising that the inverter LCL filter can be split into two separate parts to design the controllers. The LC part can be used for the voltage controller design and the grid inductor can be used for the current controller design. The voltage controller is responsible for the power quality of the local load voltage (microgrid voltage), power distribution within the microgrid and synchronisation with the grid. The current controller is responsible for the power exchanged between the grid and the microgrid, the power quality of the current exchanged with the grid, and the over-current protection. When the microgrid is connected to the grid, both controllers are active; when the microgrid is not connected to the grid, the current controller works with zero current reference. Hence, no extra effort is needed when changing the operation mode of the microgrid, which considerably facilitates the smooth operation of grid-connected inverters (Yao et al. 2010). It also shows that there is no need to consider the processing delay Wd considered in Chapter 5. 6.1 Operation Modes in Microgrids M

文档评论(0)

masterchief216 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:5114101340000003

1亿VIP精品文档

相关文档