STEP 7 Error CodesVersion 01/2014

STEP 7 Error Codes

Version 01/2014

Page

Page PAGE 10 / 39

Error number:

Text:

Cause:

Remedy:

1:2063

TBI error 2063 Error during the function chdir

TBI can occur with the call AUTgetlinkedObjects. There should be an

AUT API tracer in the meantime.

7:6160

CPUs can only be connected via K bus or MPI bus

(line 1)

Split the desired path of the global data into several circuits. Make sure that

you only use on bus per circuit.

11:103

Cannot read CPU information on module, such as rated type, actual type and status of the module. Module might not be configured.

Check the logical address of the module. Check the slot and the configured slot.

13:31

The online connection from the PG to the module (SDB addressee) could not be set up. Connection hardware is faulty (e.g